– constant throughout the warranty period
Continuous supervision from "Customer" and "Service" levels.
Separation of the boiling electrolyte from the circulating water ensures safety.
The controller ensures proper boiler operation. It enables online monitoring as well as remote adjustments.
The stainless steel heat exchanger ensures long life and dynamic heat exchange.
The boiler insulation made of foamed rubber effectively minimizes heat loss.
The main element of the SONIC boiler are patented sonic heaters,
which provide fast and safe water heating.
The first installation option for the sonic boiler is its direct connection to the home heating circuit. This option is recommended for houses: with mixed heating systems, with an energy performance class from B to D, where there is no need for DHW heating.
The second installation option for the sonic boiler is its indirect connection to the home heating circuit via a central heating buffer tank. This option is recommended for houses: with mixed or 100% underfloor heating systems, with an energy performance class from A to A++, where there is no need for DHW heating.
The third installation option for the sonic boiler is its direct connection to the home heating circuit + domestic hot water heating. This option is recommended for houses: with mixed heating systems, with an energy performance class from B to D, when there is a need for DHW heating.
The fourth installation option for the sonic boiler is its indirect connection to the home heating circuit via a central heating buffer tank + domestic hot water heating. This option is recommended for houses: with mixed or 100% underfloor heating systems, with an energy performance class from B to D, when there is a need for DHW heating.
Thanks to the use of a cylindrical boiler design, modern rubber insulation, sonic heaters immersed in a uniquely formulated electrolyte, the steam generated in the SONIC boiler transfers thermal power to the water collected in the installation almost instantly.
Calculate the time in which the boiler will heat a given volume of water and the power necessary to heat it. Fill in the fields below correctly, and after pressing the "CALCULATE" button, you will get the result.
Space heating with a sonic boiler was designed not only for single-family housing but also for industry. The SONIC boiler is a one-of-a-kind device designed to heat both small residential spaces and large-scale production halls, offices, or buildings with a large heated volume.
The boiler's heat exchanger is made of stainless steel, forming a monolith with the heating chamber made of the same material, which makes the structure highly durable and maintains a constant heating efficiency. The large surface area ensures fast and dynamic heat exchange with the circulating water. Furthermore, the circulating water is not brought to a boiling point, preventing the precipitation of "boiler scale" and increasing the lifespan of the central heating system.
| Parameter | Unit | Model | |||
|---|---|---|---|---|---|
| 10 | 15 | 20 | |||
| Dimensions | L | [mm] | 460 | ||
| H | [mm] | 1403 | |||
| H1 | [mm] | 536 | |||
| H2 | [mm] | 1126 | |||
| S | [mm] | 520 | |||
| Basic fuel | — | Three-phase electrical supply | |||
| Heat output range* | [kW] | 10 | 15 | 20 | |
| Minimum capacity of the buffer tank | [L] | 700 | |||
| Heated volume** | [m³] | 400 | 600 | 800 | |
| Heated floor area** | [m²] | 160 | 240 | 320 | |
| Boiler water capacity | [L] | 16.5 | |||
| Maximum operating pressure | [bar] | 3 | |||
| Water supply temperature min./max | [°C] | - / 85 adjustable | |||
| Boiler electrical supply 230 V – 50 Hz / 400 V – 50 Hz | [W] | 3L – N 400V | |||
| Maximum current consumption | [A] | 18 | 22 | 33 | |
| Rated current of the overcurrent circuit breaker | [A] | 25 | 40 | ||
| Minimum cross-section of the power cord | [mm²] | 5 × 2.5 | 5 x 4 | 5 x 6 | |
| Electrical power | [W] | 10 800 | 14 700 | 20 700 | |
| Standby power | [W] | 7 | |||
| Power consumption at 100% load | [W] | 10 800 | 14 700 | 20 700 | |
| Noise | [dB] | 28 | |||
| Weight (dry) | [kg] | 120 | 125 | ||
| Diameter of supply and return connections | [inch] | 1" male thread | |||
| Energy class | — | D | |||
| Controller | — | YES | |||
| Warranty | — | 5 years | |||
| Heat exchanger material | — | 316 Steel | |||
| Temperature setting range on the controller | [°C] | 20 / 80 | |||
| Protection degree | — | IP 21 | |||
| Color touch display with room thermostat | — | YES | |||
| Possibility of connecting two additional thermostats | — | YES | |||
| Ability to read and analyze data from sensors | Circulation pump | — | YES | ||
| DHW pump | — | YES | |||
| CH pump | — | YES | |||
| Mixing valves | — | YES | |||
| Buffer pump | — | YES (1 sensor) | |||
| Online boiler monitoring | Data history | — | YES | ||
| Alarms | — | YES | |||
| Work schedule | — | YES | |||
| Graphic visualization of system operation | — | YES | |||
| Service support | — | YES | |||
| Outdoor sensor support | — | YES | |||
| Automatic switching to summer/winter mode | — | YES | |||
ul. Eugeniusza Kwiatkowskiego 43
27-200 Starachowice
POLAND
tel. +48 41 2745353
fax +48 41 2745326
e-mail: export@pereko.pl