– constant during the whole guarantee period
Permanent supervision from the “Customer” and “Service” levels.
Steam generated from boiling electrolyte heats the heat exchanger with water.
The controller takes care of the correct operation of the boiler within the range of set heating cycles and indicated power tariff. It allows online monitoring of operation and remote modifications of operation settings from your smartphone, tablet or computer.
Heat exchanger and heating chamber made of stainless steel constitute the monolith, which makes that the design distinguishes with long service life. A large heating area ensures dynamic heat exchange with the circulating water.
Boiling of electrolyte at temp. ~ 70°C results in the generation of steam at temp. ~ 100°C what gives max. temp. on boiler outlet: ~ 70°C. The process is immediate, which makes that the SONIC boiler optimally cooperates with all systems: with floor warming, radiator, and combined systems.
Boiler insulation made of foamed rubber is completely waterproof. Boiler design ensures high efficiency and limits heat losses to the minimum.
The main heating component of the SONIC boiler is sonic heaters executed in a unique and patented solution. By using this technology, the water heating process in the central heating and domestic hot water systems is exceptionally quick and safe.
Specially designed electrolyte, which unique composition ensures stable operation of the equipment for many years and makes that the SONIC boiler is not only productive but also very efficient equipment preheating the water in the central heating system in a very short time.
The first range of operation of the sonic boiler is connecting it directly to the domestic heating cycle. Use of this range of installation is recommended for the homes: with mixed heating system, with building energy performance rating from B to D where it is not required to heat the domestic hot water.
The second range of operation of the sonic boiler is connecting it indirectly to the domestic heating cycle via the central heating buffer tank. Use of this range of installation is recommended for the homes: with mixed heating system or 100% floor warming, with building energy performance rating from A do A++, where it is not required to heat the domestic hot water.
The third range of operation of the sonic boiler is connecting it directly to the domestic heating cycle + heating of domestic hot water. Use of this range of installation is recommended for the homes: with mixed heating system, with building energy performance rating from B to D where it is required to heat the domestic hot water.
The fourth range of operation of the sonic boiler is connecting it indirectly to the domestic heating cycle via the central heating buffer tank + heating of domestic hot water. Use of this range of installation is recommended for the homes: with mixed heating system or 100% floor heating, with building energy performance rating from B to D where it is not required to heat the domestic hot water.
The cylindrical design of the boiler, modern rubber insulation, sonic heaters immersed in the electrolyte with a unique composition, steam generated in the SONIC boiler transfers almost immediately whole thermal power to water accumulated in the system.
Calculate a time that is required for the boiler to heat the set amount of water and the power that is necessary to heat it up. Fill the below fields correctly and you will obtain results after pressing the “CALCULATE” button.
The heating of rooms using a sonic boiler has not been designed only for single-family housing but also for industrial buildings. The SONIC boiler is a unique device intended for heating of both small residential rooms and large-footprint production floors, offices or buildings of large internal volume.
The boiler’s heat exchanger is made of stainless steel and constitutes a monolith with a heating chamber made of the same material, which makes that the design distinguishes with high service life and constant energy performance. Large area ensures quick and dynamic heat exchange with the circulating water. Circulating water is not brought to boiling point what prevents precipitation of the “boiler scale” and increases the service life of the central heating system.
The whole excess amount of the electrical energy, which has been generated by the photovoltaic system and accumulated in the DSO grid, can be used for heating rooms using a sonic boiler. The prosumers may collect 80% of their energy from the grid and use it during other periods, e.g. for heating of the home.
Building energy-efficiency rating | Size of the photovoltaic system [kWp] | Annual heating cost |
---|---|---|
A++ | 5,31 | 0$ |
A+ | 5,83 | |
A | 9,45 | |
B | 16,16 | |
C | 21,84 | |
D | 28,66 |
Building energy-efficiency rating | Size of the photovoltaic system [kWp] |
---|---|
A++ | 5,31 |
A+ | 5,83 |
A | 9,45 |
B | 16,16 |
C | 21,84 |
D | 28,66 |
Using available “night tariffs” available from your electrical energy supplier the costs of currently used for heating of home can be even two times smaller than is the case of the standard version.
Do you have the photovoltaic system installed? Are you a prosumer? If yes, your electric utility company may add power factor penalty charges to your bill. Installing the sonic boiler, which takes care to maintain this parameter on the correct level, you do not have to worry about the energy security of your home.
Parameter | Unit | Model | ||
---|---|---|---|---|
10 | 15 | |||
Dimensions | L | [mm] | 460 | |
H | [mm] | 1403 | ||
H1 | [mm] | 536 | ||
H2 | [mm] | 1126 | ||
S | [mm] | 520 | ||
Primary fuel | — | Three-phase power supply | ||
Thermal power range | [kW] | 10 | 15 | |
Min. capacity of the buffer tank | [L] | 700 | ||
Volume of heated rooms | [m³] | 400 | 600 | |
Area of heated rooms | [m²] | 160 | 240 | |
Boiler water tank capacity | [L] | 16,5 | ||
Max. permissible work pressure | [bar] | 3 | ||
Min./max. supply water temperature | [°C] | - / 85 adjustable | ||
Electric supply of the boiler 230V - 50Hz / 400V - 50Hz | [W] | 3L – N 400V | ||
Maximum power consumption | [A] | 18 | 22 | |
Rated current of overcurrent circuit breaker | [A] | 25 | ||
Minimum cross-section of power cable | [mm²] | 5 × 2,5 | 5 x 4 | |
Electric power | [W] | 10 800 | 14 700 | |
Power at standby mode | [W] | 7 | ||
Power input for 100% loading | [W] | 10 800 | 14 700 | |
Noise | [dB] | 28 | ||
Boiler weight without water | [kg] | 120 | 125 | |
Supply and return socket diameter | [cal] | GZ 1" | ||
Energy class | — | D | ||
Controller | — | YES | ||
Warranty | — | 5 years | ||
Heat exchanger material | — | Steel 316 | ||
Range of temperature settings on the controller | [°C] | 20 / 80 | ||
Degree of protection | — | IP 21 | ||
Colour touch display with room thermostat | — | YES | ||
Option to connect two additional thermostats | — | YES | ||
Option to read and analyse data from the sensors | Circulating pump | — | YES | |
DHW pump | — | YES | ||
Central heating pump | — | YES | ||
Mixing valves | — | YES | ||
Buffer pump | — | YES (1 sensor) | ||
Online monitoring of boiler operation | Data history | — | YES | |
Alarms | — | YES | ||
Operation schedule | — | YES | ||
Graphic visualization of system operation | — | YES | ||
Service assistance | — | YES | ||
External sensor support | — | YES | ||
Automatic switching between summer and winter mode | — | YES |