HEAT PUMPS 
TERMOSTAR ECO PLUS

pompy ciepła termostar eco plus

SAVE MONEY 
SAVE THE ENVIRONMENT

bar
resistance of the heat pump to low temperatures

frostproof

The pump has additional heating elements for low-temperature operation.

inverter in heat pump

INVERTER

It features precise water temperature control, higher efficiency, smoother start-up, wider operating range and longer compressor life.

energy class of heat pump

An efficient air source heat pump, achieving energy efficiency of A++ at 55°C and A+++ at 35°C.

heat pump monobloc

An easy-to-install unit that contains all the components needed to generate heat.

R32 refrigerant

The pump uses R32 refrigerant, which has a low greenhouse gas creation factor.

the volume of the heat pump

One of the quietest heat pumps on the market, with a maximum noise level of 42 dB.

heat pump guarantee

UP TO 5 YEARS
GUARANTEE

The heat pump is guaranteed for up to 5 years.

Manage your device's operation online with the EX300 app

ex300
heat pump construction
nr 1

The compact design of the heat pump (monoblock) contains all the components necessary for efficient operation and rapid heat generation. It allows the use of a small amount of R32 refrigerant, easy installation and low-cost servicing.

nr 2

The Mitsubishi compressor at the heart of the heat pump makes it efficient and quiet (<42 dB.). It allows the heat pump to produce hot water for the central heating system or domestic hot water.

nr 3

The TERMOBOX indoor unit includes: instantaneous water heater, circulating pump, expansion vessel, 3-way valve, safety valve, mesh filter and air vent. TERMOBOX reduces installation costs and speeds up installation.

nr 4

The TERMOSTAR ECO PLUS heat pumps have advanced controls for programming the unit's operation, domestic hot water preparation, monitoring operation and heat production. The wireless WiFi control system enables the unit to be controlled from anywhere in the world.

Contact us to obtain more information:

CONNECTING THE HEAT PUMP 
TO THE INSTALLATION

bar
heat pump installation diagram - CO buffer tank

CONNECTION OF THE HEAT PUMP TO THE CENTRAL HEATING SYSTEM.

The heat pump should always be connected to the central heating system via a buffer tank.

isoB02
heat pump installation diagram - CH and DHW buffer tanks

CONNECTION OF THE HEAT PUMP TO THE CENTRAL HEATING + DHW SYSTEM.

Always connect the heat pump to the central heating system via a buffer tank. Use an enamelled tank with a coil for domestic hot water.

isoB04

Contact us to obtain more information:

FREE HEATING? 
– IT'S POSSIBLE!

bar

Owners of the photovoltaic power stations can use DSO electricity grids as an accumulator, storing the excess of electrical energy generated in the domestic PV system, when it is not consumed in the house and it allows using it during the evening or on days when the energy demand is higher.

heat pumps and photovoltaics

The recommended size of a photovoltaic system

Heated area: 140 m²
Number of inhabitants: 2 adults, 2 children
Averaged SCOP of the heat pump: 3.5
Building energy-efficiency rating Size of the photovoltaic system [kWp] Annual heating cost
A++ (10 kWh/m²/year) 1.8 0$
A+ (15 kWh/m²/year) 2.7
A (35 kWh/m²/year) 6.3
B (60 kWh/m²/year) 10.9
C (90 kWh/m²/year) 16.3
D (130 kWh/m²/year) 23.6
Building energy-efficiency rating Size of the photovoltaic system [kWp]
A++ 1.8
A+ 2.7
A 6.3
B 10.9
C 16.3
D 23.6
Annual heating cost: 0$

Contact us to obtain more information:

TECHNICAL 
DOCUMENTATION

bar
Parameter Unit TERMOSTAR ECO PLUS
TSE-PC6-R32-M-HB TSE-PC9-R32-M-HB TSE-PC12-R32-M-HB TSE-PC18-R32-M-HB
Dimensions Outdoor unit mm 1115/425/898 1115/425/982 1115/425/1322
Termobox 530/262/650
Energy efficiency class A+++
Heating power kW 1,2-7 2-10 4-13 6-20
SCOP Seasonal Coefficient of Performance in heating mode W/W 4,77 4,67 4,94 4,95
Nominal cooling output kW 6,25 8,99 11,0 17,82
Nominal electrical power in cooling mode kW 1,54 2,41 3,08 4,92
Voltage/frequency/phase V/Hz 230/50/1
Maximum electrical power consumption kW 2,76 3,45 3,9 5,5
Compressor type Mitsubishi / Twin Rotary
Refrigerant R32
Amount of refrigerant kg 1,5 2,25 2,80 3,9
Noise level Outdoor unit dB(A) 41 44 47 49
Termobox 35
Maximum heating water outlet temperature Outdoor unit °C 58
Termobox 60
Heating water pressure range bar 0,5/3,0 0,5/3,0 0,5/3,0 0,5/3,0
Operating range/outdoor air temperature in heating mode -15°C/58°C
Operating range/outdoor air temperature in heating mode with heater -25°C/58°C
Net weight Outdoor unit kg 80 83 125 175
Termobox 15 16 17
installation

ADVICE AND INSTALLATION

  • expert advice,

  • installation of heat pumps exclusively by Certified Installers with PEREKO Authorisation Certificate,

  • assembly of hydraulic and electrical components and peripheral elements such as central heating and hot water tanks,

  • removal of the old installation and installation of the new installation (plumbing and electrical) within the boiler,

  • dismantling of old heating installations - room preparation.

wielkość pompy ciepła

MONOBLOC CONSTRUCTION

Complete equipment - assembly in 1 day!

Contact us to obtain more information:

PEREKO sp. z o.o.

ul. Eugeniusza Kwiatkowskiego 43
27-200 Starachowice
POLAND


tel. +48 41 2745353
fax +48 41 2745326
e-mail: bok@pereko.pl